  • Rated. / 5. Based on customer reviews
Page view 7
Intended Use
The 911D Powerig is designed to be used
with Huck Installation Tools (refer to
Utilisation on Page 5), to install various
Huck Bobtail Fasteners, in a factory
(where permitted),or outdoor working
environment. The unit should be not be
placed on a surface with an angle
exceeding 15 degrees from the horizontal.
Noise
The sound measurement is in accordance
with BS EN ISO 3746: 1996 is less than
70dB(A).
Disposal
Fluids should be disposed of by
processing through authorised methods
and in accordance with current legislation.
This symbol indicates that this product
must be disposed of according to the
WEEE Directive and our national law.
Products of this nature should be
forwarded to a designated collection point
e.g. on an authorised one-for-one basis
when you buy a similar new product or to
an authorised collection site for recycling
waste electrical and electronic equipment
(EEE). Improper handling of this type of
waste could have a possible negative
impact on the environment and human
health due to potentially hazardous
subst ances that are generally associated
with EEE. At the same time, your co-
operation in the correct disposal of these
product s will contribute to the ef fective
usage of natural resources.
Special Note
The 911D Series Powerigs include a 12
VDC 55 Amp Hour Lead Acid Battery.
Batteries are classed as hazardous waste
and should be disposed of in accordance
with legal requirement s.
For more information with respect to the
management of waste equipment for
recycling please cont act our Customer
Services desk at Alcoa Fastening
Systems Ltd, Telford Shropshire TF3 3BQ.
The Producer Identification Number for
Alcoa Fastening Systems Lt d, Telford is:
WEE/AF0044SY
The Waste Electrical &
Electronic Equipment
Regulations 2006
CAUTION
THE HYDRAULIC OUTPUT PRESSURE
VALVES (PULL & RETURN) ON THIS
POWERIG MAY HAVE BEEN SET AND
SEALED BY THE MANUFACTURER
AND SHOULD ONLY BE CHANGED IN
ACCORDANCE WITH THE
INSTRUCTIONS SHOWN IN THIS
MANUAL.
ANY NEW PRESSURES SET MUST
ALWAYS BE CHECKED AND TESTED.
CAUTION
THE POWERIG SHOULD NOT BE USED
AS A STEP. NO PERSON SHOULD
CLIMB ON THE POWERIG.
CAUTION
THE POWERIG SHOULD NOT BE USED
IN AN EXPLOSIVE AND/OR HIGHLY
FLAMMABLE ATMOSPHERE
Notes:
1) If the Powerig is delivered without an Installation Tool, Pull Pressure is factory preset at
510 bar, (7400 psi).
2) If the Powerig is delivered without an Installation Tool, Return Pressure is factory
preset at 221 bar, (3200 psi).