9
SFBTT20-IT BOBTAIL Installation Tool Alcoa Fastening Systems
Figure 4
128441-3 C
128441-3 C
ONTROLLER
ONTROLLER
UL & Serial
No. Sticker
Instructions &
Wiring Diagram
Digital
Display
PLC
Arrow
Buttons
Command
Buttons
ESC - MENU - ENT
3-Position
Mode
Switch
AS SHIPPED:
Controller Pressure:
4200 psi.
Hold Timer:
500 (.50 seconds).
Eject Timer:
600 (.60 seconds).
1. Move the 3-Position Mode Switch on the PLC to
“STOP” (right-most position).
2. Press the MENU Command Button to enter the
“Monitor” menu.
3. Press the ENT Command Button to select “Data
Monitor”. Press ENT again to select “V” data type.
4. Enter the address button of the value you need to
alter. Use the left (◄ ) and right ( ►) buttons to
position the cursor. Use the up ( ▲ ) and down
( ▼ ) buttons to change individual digits. Press
the ENT Command Button when finished.
5. Press the ENT Command Button to enter the
“Change” menu.
6. Use the arrow buttons again to enter the new
value. Press ENT when finished.
7. Press the ESC Command Button 5 times to exit.
8. Move the Mode Switch back to “RUN” (left-most
position).
9. Check the continuously scrolling display for your
new value before using the Tool again.
“V“
ADDRESS
DESCRIPTION RANGE DEFAULT UNITS
07411 T1 Press. SetPt 1000-9999 4200 psi
07412 T2 Press. SetPt 1000-9999 4200 psi
07413 T3 Press. SetPt 1000-9999 4200 psi
07421 T1 Hold Timer 0-3000 500 msec
07422 T2 Hold Timer 0-3000 500 msec
07423 T3 Hold Timer 0-3000 500 msec
07431 T1 Eject Timer 250-3750 600 msec
07432 T2 Eject Timer 250-3750 600 msec
07433 T3 Eject Timer 250-3750 600 msec
SET POINT ADJUSTMENTS
The active set points are displayed continuously while the Controller is in RUN mode. Stopping the Controller (which
also stops Tool sequencing) allows the user to enter the Controller menu to make adjustments. Do not begin this
procedure if any of the Tools are still in use.
M 3 : D A T A T Y P E V
A D D R E S S 0 0 0 0 0
M 3 : > D A T A M O N I T O R
> B I T M O N I T O R
M 3 : D A T A V 0
C H G = 0 0 0 0 0 0 0 0